Immersion Tank Specs

Exterior Sized at roughly 25in x 18in x 22in (L63cm x W45cm x H56cm)

For Maximum thermal efficiency and space saving

Immersion Tank

  • Interior sizing dimensions for Miner

    • 24.8in x 8.9in x 13.7in

    • 630mm x 225mm x 350mm

  • Two C20-c13 splitter cables included

  • Two Ethernet Cables (for in tank) included

  • ​Integrated Pump, PDU, and Network switch for easy install

  • Two flow plates included

    • S19/21 custom flow to essential components

    • Universal "one size fits all" for other miners

  • ​Kink and UV resistant Hose included for 8m (26ft) distance from tank to drycooler

TankDimensions.png
LEFT.png

Design

  • Locking Lid to Prevent unauthorized opening​

    • Safer for family

  • Casters For easy movement around space

    • ability to lock in place if desired

  • Integrated Network switch and PDU for minimizing wiring outside box and ease of installation

    • More economical instead of running two long Ethernet cords and two separate 10/2 circuits to your box, just need one circuit (50amp) allowing power and internet management from the tank

  • PDU capable of remote power use monitoring

  • Push connect fittings and heat exchanger included for easy integration to existing heating circuits
    • Preheat/heat domestic hot water, replace radiant floor or hydronic boilers, heat a greenhouse, use cases are endless